  • HOT WATER MODELS S-34 THROUGH S-150

    2017-4-12 · B. 1. This device must be installed after the boiler draft hood (between the draft hood outlet and the connector to the out-door chimney or vent) as close to the draft hood as practi-cable, and without modification of the draft hood or the vent damper. (See figures 1, 2 and 3.) 2. The inlet size of the vent damper must be the same nomi-nal ...

    Get Price
  • MEA 155-00-M

    2021-6-15 · sensor, combination gas pressure regulator, hot water temperature limit control pressure relief valve rated at 30 psig and vertical cone type draft hood. Full scale operational tests for safety were performed to include factory supplied automatic vent damper assembly (suffix SPD or PID). Units, with model numbers and input

    Get Price
  • CANADIAN ENERGY VERIFIE GAS-FIRED CAST-IRON

    2021-1-19 · DRAFT HOOD The draft hood supplied with SE models is part of the listed boiler assembly. DO NOT alter the hood. See dimensions, page 2. Attach the hood to the boiler flue outlet. Connect flue pipe full size of hood outlet. Vent damper must be installed on the out-let side of the hood. See Vent Piping, below. VENT PIPING

    Get Price
  • Installation, Operating and Service Instructions for RRG ...

    2019-8-28 · Components Shipped with Boiler: Draft hood Vent damper Circulator Miscellaneous parts bag (Supply water manifold, Temperature/pressure gauge, 30 psi safety relief valve, drain valve, circulator flanges) Conversion Kits RRG067E RRG100E RRG134E RRG167E RRG201E RRG234E RRG268E Natural Gas to LP (0-2,000 ft) 109706-01 109706-02

    Get Price
  • Caravan Gas Hot Water Installation and Operating Instructions

    2020-4-29 · This boiler, gas piping and accessories must be installed, con-nected, serviced and repaired by a trained, experienced service technician, familiar with all precautions required for gas fired equipment and licensed or otherwise qualified, in compliance with the authority having jurisdiction. HOT WATER—Models GG-300 through GG-399HES

    Get Price
  • GAS SPILLAGE SENSING KIT - Field Controls

    2019-6-27 · VERTICAL DRAFT HOOD (See Figures 5 & 6 or Figure 13 for water heaters) 1. Two (2) switches are recommended on appliances without a factory supplied spill switch. Mount the spill switch onto the bottom edge of the draft hood and the second switch (if used) approximately 90O from the first switch or 90O from the factory supplied switch. (See ...

    Get Price
  • GWA - Williamson-Thermoflo

    2019-12-12 · GWA Gas-Fired Water Boilers oiler Manual Installations must follow these codes: • Local, state, provincial, and national codes, laws, regulations ... Do not add cold water to hot boiler. Thermal shock can ... Do not alter boiler draft hood or place any obstruction or non-certified vent damper in breeching or vent

    Get Price
  • Part VI—Fuel Gas - Seattle

    2013-12-26 · excessive draft and backdraft. BOILER, LOW-PRESSURE. A self-contained gas-fired appliance for supplying steam or hot water. Hot water heating boiler. A boiler in which no steam is generated, from which hot water is circulated for heating purposes and then returned to the boiler, and that operates at water pressures not exceeding 160 psig (1100 kPa

    Get Price
  • Standard P&ID Symbols Legend

    2020-12-29 · Gas blower Vertical pump Liquid ring vacuum pump Positive displacement pump Horizontal pump ... Boiler Condenser Extractor Hood Hose reel Light Water Station Combustion Chamber Silencer Thin-Film Evaporator ... Gas bottle Boiler Dome Boiler Hot Liquid Boiler Tank Tank 2 Tank 3 Tank 4 Open tank Covered Tank

    Get Price
  • Accessories and Services - Parker Boiler

    The Parker Boiler Heat Reclaimer is a device designed to reclaim heat in the form of additional hot water from exhaust stacks of gas and oil burning appliances. On Parker Steam & Hot Water Boilers and Indirect Fired Heaters it is inserted in the vent stack between the boiler and the draft hood or barometric damper.

    Get Price
  • Turbulators

    For example, a two-pass boiler provides two opportunities for hot gases to transfer heat to the boiler water. Hot combustion gases enter the tubes in a turbulent flow regime, but within a few feet, laminar flow begins and a boundary layer of cooler gas forms along the tube walls. This layer serves as a barrier, retarding heat transfer.

    Get Price
  • WPSB Series 3

    2021-8-25 · Efficiency: Mid-Efficiency Capacity: Natural Gas (D Models): 75 - 112.5 - 150 - 187.5 - 225 - 262 - 299 MBH Propane (DP Models): 70 - 105 - 140 - 175 - 210 - 245 - 280 MBH; Heat Exchanger: Cast Iron Combustion: Atmospheric Venting: Chimney Vent Boiler Type: Hot Water Boiler Control Module: Fuel Smart Hydrostat Temperature Limit, LWCO and Boiler Reset Control with Circulator Relay and …

    Get Price
  • Weil-McLain CGI Gas Boiler

    Download Weil-McLain CGI Gas Boiler Brochure PDF - (2.03MB) Click here to schedule a free, no obligation, consultation today! 141 Kenilworth Avenue North. Hamilton, ON L8H 4R9. Phone: 905-549-4616. Fax: 905-549-8225. Hours.

    Get Price
  • 10 Best Water Filters in Malaysia (2021) For Clean Water ...

    2021-7-15 · Table of contents. Top 10 Best Water Filters & Water Purifiers in Malaysia. 1. Our best pick: 3M CTM-01 SE Countertop Drinking Water Filter 2. Long cartridge life: Panasonic Water Purifier TK-CS20 3. More hot water: Cuckoo VIVID 4. Multi-step filtration: Coway P07IU Water Purifier 5.

    Get Price
  • Gas Water Heater Venting Options

    Melted plastic of the water inlet/outlet rings, located on top of the water heater and close to the draft hood. Exhaust gases can condense at the top of the heater and cause corrosion. Heavy condensation can also occur on the nearby cold water pipes. To prevent the problem, do the following to check for the proper draft at a water heater:

    Get Price
  • How To Vent a Gas Water Heater

    2020-7-14 · Similar to a furnace, water heaters with gas burners will generate harmful fumes containing carbon monoxide, a byproduct of the fuel used to ignite the burner to heat the water in the tank, whether that fuel is natural gas, oil, or propane. Just like with your furnace, you need to have proper venting to exhaust the water heater's toxic fumes to the outside of the home to keep you and your ...

    Get Price
  • VENTING VENTING Gas AppliancesGas Appliances

    2013-6-18 · Draft-hood units require an additional 14 or 15 cu.ft. of dilution air for each 1 cu.ft. of fuel consumed, producing roughly 30 cu.ft. of relatively drier exhaust products for the flue to handle. (The ratios are slightly different for propane, but the principle is the same.) This difference between fan-assist and draft-hood performance has an ...

    Get Price
  • Languages - Hot Water

    Depending on how much hot water you actually use, you might not even notice the loss in capacity. If you do notice, or if you don't want to take the risk, we recommend installing a thermostatic mixing valve. That will enable you to safely increase the temperature of your water heater and maximize the hot water …

    Get Price
  • Draft Measurement Guide for Chimneys & Flues

    Normally we measure draft at two locations: over the fire or in the combustion chamber where typically we may see -0.02 to -0.03 inches of water column pressure, and in the breech or at the stack pipe (properly, the flue vent connector) measured just a few inches above the boiler or furnace top, and before the barometric damper itself.

    Get Price
  • WPSB Series 3

    2021-8-25 · Efficiency: Mid-Efficiency Capacity: Natural Gas (D Models): 75 - 112.5 - 150 - 187.5 - 225 - 262 - 299 MBH Propane (DP Models): 70 - 105 - 140 - 175 - 210 - 245 - 280 MBH; Heat Exchanger: Cast Iron Combustion: Atmospheric Venting: Chimney Vent Boiler Type: Hot Water Boiler Control Module: Fuel Smart Hydrostat Temperature Limit, LWCO and Boiler Reset Control …

    Get Price
  • DXL Series

    2021-9-2 · DXL Series. Dunkirk's DXL Series of gas-fired hot-water boilers have an advanced Fuel Smart Hydrostat Control and offers up to 83.5% AFUE. Energy saving features include the electronic ignition system and motorized vent damper to reduce your heating costs. Features a dependable cast iron heat exchanger with cast iron push nipple connections.

    Get Price
  • Checking Water Heater Vent Draft

    2020-2-28 · Checking the Vent Installation. The fume hood should be sitting on the tank level. The vertical legs should be straight and inserted in the slots provided. The fume hood should be directly over the round opening in the top of the hot water heater. …

    Get Price
  • Gas Water Heater Venting Options

    Melted plastic of the water inlet/outlet rings, located on top of the water heater and close to the draft hood. Exhaust gases can condense at the top of the heater and cause corrosion. Heavy condensation can also occur on the nearby cold water pipes. To prevent the problem, do the following to check for the proper draft at a water heater:

    Get Price
  • VENTING VENTING Gas AppliancesGas Appliances

    2013-6-18 · Draft-hood units require an additional 14 or 15 cu.ft. of dilution air for each 1 cu.ft. of fuel consumed, producing roughly 30 cu.ft. of relatively drier exhaust products for the flue to handle. (The ratios are slightly different for propane, but the principle is the same.) This difference between fan-assist and draft-hood performance has an ...

    Get Price
  • Turbulators

    For example, a two-pass boiler provides two opportunities for hot gases to transfer heat to the boiler water. Hot combustion gases enter the tubes in a turbulent flow regime, but within a few feet, laminar flow begins and a boundary layer of cooler gas forms along the tube walls. This layer serves as a barrier, retarding heat transfer.

    Get Price
  • Everbilt Water Heater Vent Hood-EB40665 - The Home Depot

    2020-7-8 · Everbilt's Vent Hood Replacement contains everything that you need to replace the vent hood on your gas water heater. The part is required anytime the vent hood is damaged or missing. The Vent Hood ensures the safe and reliable operation of your gas water heater.

    Get Price
  • Languages - Hot Water

    Depending on how much hot water you actually use, you might not even notice the loss in capacity. If you do notice, or if you don't want to take the risk, we recommend installing a thermostatic mixing valve. That will enable you to safely increase the temperature of your water heater and maximize the hot water output.

    Get Price
  • Weil-McLain CGI Gas Boiler

    Download Weil-McLain CGI Gas Boiler Brochure PDF - (2.03MB) Click here to schedule a free, no obligation, consultation today! 141 Kenilworth Avenue North. Hamilton, ON L8H 4R9. Phone: 905-549-4616. Fax: 905-549-8225. Hours.

    Get Price
  • House Water Heater Vent Pipe Tips & How To Do It Right ...

    2008-3-19 · On top of natural draft gas water heater, in its center section, right above the water heater vent, you should have a draft hood installed. It sits on 3-4 short legs, sometimes secured to the water heater top plate with screws, or ( depending on design ) has its legs shaped like pins or hooks at the end, inserted into the holes in water heater ...

    Get Price
  • GAS SPILLAGE SENSING KIT - Field Controls

    2019-6-27 · VERTICAL DRAFT HOOD (See Figures 5 & 6 or Figure 13 for water heaters) 1. Two (2) switches are recommended on appliances without a factory supplied spill switch. Mount the spill switch onto the bottom edge of the draft hood and the second switch (if used) approximately 90O from the first switch or 90O from the factory supplied switch. (See ...

    Get Price
  • VENTING VENTING Gas AppliancesGas Appliances

    2013-6-18 · Draft-hood units require an additional 14 or 15 cu.ft. of dilution air for each 1 cu.ft. of fuel consumed, producing roughly 30 cu.ft. of relatively drier exhaust products for the flue to handle. (The ratios are slightly different for propane, but the principle is the same.) This difference between fan-assist and draft-hood performance has an ...

    Get Price
  • DXL Series

    2021-9-2 · DXL Series. Dunkirk's DXL Series of gas-fired hot-water boilers have an advanced Fuel Smart Hydrostat Control and offers up to 83.5% AFUE. Energy saving features include the electronic ignition system and motorized vent damper to reduce your heating costs. Features a dependable cast iron heat exchanger with cast iron push nipple connections.

    Get Price
  • Checking Water Heater Vent Draft

    2020-2-28 · Checking the Vent Installation. The fume hood should be sitting on the tank level. The vertical legs should be straight and inserted in the slots provided. The fume hood should be directly over the round opening in the top of the hot water heater. …

    Get Price
  • Series GM

    2021-5-3 · • An external energy management system is installed that reduces the boiler water temperature as the heating load decreases. • This boiler is not used for any space heating • This boiler is part of a modular or multiple boiler system having a total input of 300,000 BTU/hr or greater. • This boiler is equipped with a tankless coil. IMPORTANT

    Get Price
  • EXAMINATION SYLLABUS FOR ENGINEER'S CERTIFICATE

    2013-1-16 · (a) Steam and Hot Water Boilers Different types of boilers (e.g. fire and water tubes boilers, vertical shell type, multitubular underfired, economic package and waste heat); Constructional details; Mountings and fittings (e.g. water level gauges, steam pressure

    Get Price
  • Languages - Hot Water

    Depending on how much hot water you actually use, you might not even notice the loss in capacity. If you do notice, or if you don't want to take the risk, we recommend installing a thermostatic mixing valve. That will enable you to safely increase the temperature of your water heater and maximize the hot water output.

    Get Price
  • Gas-Fired Boilers - Code Compliance Brief

    The intent of this brief is to provide code-related information about gas-fired boilers to help ensure that the measure will be accepted as being in compliance with the code. Providing notes for code officials on how to plan reviews and conduct field inspections can help builders or remodelers design installations and prepare construction documents, and provide jurisdictional officials with ...

    Get Price
  • Type B Vent (Gas) - AmeriVent

    AmeriVent is a complete gas venting system, from 3' to 30' pipe diameters in 7 different pipe lengths, to single- to multi-appliance hook-ups. The AmeriVent gas vent line allows you to create almost any system from our more than 350 coordinated parts. Featuring Snap-Lock joints that are quick and easy to disconnect, the AmeriVent Type B gas ...

    Get Price
  • House Water Heater Vent Pipe Tips & How To Do It Right ...

    2008-3-19 · On top of natural draft gas water heater, in its center section, right above the water heater vent, you should have a draft hood installed. It sits on 3-4 short legs, sometimes secured to the water heater top plate with screws, or ( depending on design ) has its legs shaped like pins or hooks at the end, inserted into the holes in water heater ...

    Get Price
  • Water Heating System - Water Heater Malaysia

    2018-10-19 · Water Heater Malaysia. Water heating is a warmth exchange process that uses a vitality source to warm water over its underlying temperature. Run of the mill household employments of hot water incorporate cooking, cleaning, washing, and space heating. In industry, hot water and water warmed to steam have numerous employments.

    Get Price
  • Home

    FIMACO SDN BHD (110749-V) GST No: 001701969920 (A Member of Fiamma Holdings Berhad) 8-2, Wisma Fiamma, No. 20, Jalan 7A/62A, Bandar Manjalara, 52200 Kuala Lumpur, Malaysia.

    Get Price
  • Series MI Series MIHII - PB Heat: Peerless® Boilers

    2019-11-5 · The design of this boiler is certified for alcove installation with the following clearances: 1. 6″ (152 mm) between sides and combustible construction. 2. 24″ (610 mm) between top of jacket and combustible construction. 3. this boiler on non-combustible flooring or use a 6″ (152 mm) between draft hood and combustible construction.

    Get Price
  • DXL Series

    2021-9-2 · DXL Series. Dunkirk's DXL Series of gas-fired hot-water boilers have an advanced Fuel Smart Hydrostat Control and offers up to 83.5% AFUE. Energy saving features include the electronic ignition system and motorized vent damper to reduce your heating costs. Features a dependable cast iron heat exchanger with cast iron push nipple connections.

    Get Price
  • VENTING VENTING Gas AppliancesGas Appliances

    2013-6-18 · Draft-hood units require an additional 14 or 15 cu.ft. of dilution air for each 1 cu.ft. of fuel consumed, producing roughly 30 cu.ft. of relatively drier exhaust products for the flue to handle. (The ratios are slightly different for propane, but the principle is the same.) This difference between fan-assist and draft-hood performance has an ...

    Get Price
  • GOLD SERIES GAS BOILERS - Weil-McLain

    2020-5-20 · CGa boilers are C.S.A. design certified for installation on combustible flooring. DIMENSIONS STANDARD EQUIPMENT: Factory Tested Two-Piece Top Jacket Panel Insulated Extended S teel Jacket Cast Iron Sections with Built-in Air Separator Radiation Plates Vertical Draft Hood Automatic Vent Damper Combination Gas Valve

    Get Price
  • Caron Heating & Cooling, Inc., Boilers - Methuen, MA,

    If your home has hot water radiators in each room for heat, you have a boiler to heat the water. Like a furnace, the energy efficiency of a boiler is given as the Annual Fuel Utilization Efficiency (AFUE). Boilers manufactured since 1992 must have an AFUE of at least 80%. We offer a complete line of gas and oil boilers starting at 80% AFUE and up.

    Get Price
  • SHB02 -pg 30 -60b

    2021-7-14 · gas is exhausted for each 1 ft of natural gas consumed. Now consider the fact that for every 15 ft3 of flue gas going up the flue, an equal volume of dilution air is added at the draft hood. Therefore, for typical draft hood - equipped appliances, the total volume of flue gas is 30 ft3 for each 1 ft3 of natural gas burned in the combustion ...

    Get Price
  • House Water Heater Vent Pipe Tips & How To Do It Right ...

    2008-3-19 · On top of natural draft gas water heater, in its center section, right above the water heater vent, you should have a draft hood installed. It sits on 3-4 short legs, sometimes secured to the water heater top plate with screws, or ( depending on design ) has its legs shaped like pins or hooks at the end, inserted into the holes in water heater ...

    Get Price
  • ProLine® XE SL Power Direct Vent 50-Gallon ... - Hot Water

    Product Description. The ProMax® SL Power Direct Vent gas water heater offers horizontal and vertical venting options and features a two-pipe venting system that draws clean air from outside the home, eliminating any worries about indoor ventilation. Featuring a 50-gallon (nominal) tank and a 60,000 BTU propane burner, the GPDX-50L (LP) Power ...

    Get Price
  • Checking Water Heater Vent Draft

    2020-2-28 · Checking the Vent Installation. The fume hood should be sitting on the tank level. The vertical legs should be straight and inserted in the slots provided. The fume hood should be directly over the round opening in the top of the hot water heater. If it is crooked or off to one side it should be fixed.

    Get Price
  • GWA - Williamson-Thermoflo

    2019-12-12 · GWA Gas-Fired Water Boilers oiler Manual Installations must follow these codes: • Local, state, provincial, and national codes, laws, regulations ... Do not add cold water to hot boiler. Thermal shock can ... Do not alter boiler draft hood or place any obstruction or non-certified vent damper in breeching or vent

    Get Price
  • Engineering Standards Manual: Standard Drawings & Details

    2004-9-30 · LANL Standard Drawings and Details either (1) depict required format/content or (2) are templates that are completed by a Design Agency (LANL or external AE) for a design drawing package, in a manner similar to specifications.

    Get Price
  • The Function of a Draft Diverter

    A draft diverter, or draft hood, plays a vital role in the operation of a combustion chamber, such as a fireplace or furnace. The draft diverter, which consists of a baffle plate positioned directly above the primary flue, regulates the direction and amount of air flowing in and out of the burner.

    Get Price
  • Part VI—Fuel Gas - Seattle

    2013-12-26 · excessive draft and backdraft. BOILER, LOW-PRESSURE. A self-contained gas-fired appliance for supplying steam or hot water. Hot water heating boiler. A boiler in which no steam is generated, from which hot water is circulated for heating purposes and then returned to the boiler, and that operates at water pressures not exceeding 160 psig (1100 kPa

    Get Price
  • Hot Water Boiler - Manufacturers, Suppliers & Dealers

    Find listing of hot water boiler, hot water boiler manufacturers, suppliers, dealers & exporters from India. Get hot water boiler at best price from listed companies as per your buying requirements.

    Get Price
  • Caravan-Gas-Hot-Water-GG-Series-Specifications-112.doc ...

    GG Series Caravan Hot Water Gas-Fired Specification Furnish and install, in compliance with manufacturer's instructions and the rules and regulations of the authorities having jurisdiction. Modular boilers shall have a C.S.A. input of _____BTUH natural (LP) gas with a gross output of _____ BTUH and Net A.H.R.I. rating of _____ BTUH. Boiler shall be Slant/Fin Caravan Model _____ consisting of ...

    Get Price
  • DESIGN RECOMMENDATION FOR STORAGE TANKS AND

    2017-3-28 · the storage of water, spherical tanks (pressure vessels) for the storage of high pressure liquefied gases, and under-ground tanks for the storage of water and oil. The trend in recent years is for ... vertical design seismic coefficient in the ground KHS lateral design seismic coefficient at …

    Get Price
  • 248 CMR 7 Large gas utilization equipment

    2017-10-24 · Any gas utilization equipment having inputs of more then 400,000 BTU's per hour per combustion chamber. This includes, but is not limited to, steam boilers, hot water boilers, water heaters, generators, and other similar gas utilization equipment. Flame Safeguard. (See Control, Primary Safety.) Flue Gases. Products of combustion and excess air.

    Get Price
  • Draft Regulators - Barometric Dampers: A Guide to ...

    DRAFT HOOD, GAS HEATER for draft regulation on gas fired heating equipment. DAMPERS & DRAFT REGULATOR TYPES for a complete list that includes draft regulation on wood, coal, oil, and combination wood-oil fueled boiler and furnaces. GAS DETECTION INSTRUMENTS. Suggested citation for …

    Get Price
  • Water Heating System - Water Heater Malaysia

    2018-10-19 · Water Heater Malaysia. Water heating is a warmth exchange process that uses a vitality source to warm water over its underlying temperature. Run of the mill household employments of hot water incorporate cooking, cleaning, washing, and space heating. In industry, hot water and water warmed to steam have numerous employments.

    Get Price
  • Home

    FIMACO SDN BHD (110749-V) GST No: 001701969920 (A Member of Fiamma Holdings Berhad) 8-2, Wisma Fiamma, No. 20, Jalan 7A/62A, Bandar Manjalara, 52200 Kuala Lumpur, Malaysia.

    Get Price
  • Series MI Series MIHII - PB Heat: Peerless® Boilers

    2019-11-5 · The design of this boiler is certified for alcove installation with the following clearances: 1. 6″ (152 mm) between sides and combustible construction. 2. 24″ (610 mm) between top of jacket and combustible construction. 3. this boiler on non-combustible flooring or use a 6″ (152 mm) between draft hood and combustible construction.

    Get Price
  • DXL Series

    2021-9-2 · DXL Series. Dunkirk's DXL Series of gas-fired hot-water boilers have an advanced Fuel Smart Hydrostat Control and offers up to 83.5% AFUE. Energy saving features include the electronic ignition system and motorized vent damper to reduce your heating costs. Features a dependable cast iron heat exchanger with cast iron push nipple connections.

    Get Price
  • VENTING VENTING Gas AppliancesGas Appliances

    2013-6-18 · Draft-hood units require an additional 14 or 15 cu.ft. of dilution air for each 1 cu.ft. of fuel consumed, producing roughly 30 cu.ft. of relatively drier exhaust products for the flue to handle. (The ratios are slightly different for propane, but the principle is the same.) This difference between fan-assist and draft-hood performance has an ...

    Get Price
  • GOLD SERIES GAS BOILERS - Weil-McLain

    2020-5-20 · CGa boilers are C.S.A. design certified for installation on combustible flooring. DIMENSIONS STANDARD EQUIPMENT: Factory Tested Two-Piece Top Jacket Panel Insulated Extended S teel Jacket Cast Iron Sections with Built-in Air Separator Radiation Plates Vertical Draft Hood Automatic Vent Damper Combination Gas Valve

    Get Price
  • Caron Heating & Cooling, Inc., Boilers - Methuen, MA,

    If your home has hot water radiators in each room for heat, you have a boiler to heat the water. Like a furnace, the energy efficiency of a boiler is given as the Annual Fuel Utilization Efficiency (AFUE). Boilers manufactured since 1992 must have an AFUE of at least 80%. We offer a complete line of gas and oil boilers starting at 80% AFUE and up.

    Get Price
  • SHB02 -pg 30 -60b

    2021-7-14 · gas is exhausted for each 1 ft of natural gas consumed. Now consider the fact that for every 15 ft3 of flue gas going up the flue, an equal volume of dilution air is added at the draft hood. Therefore, for typical draft hood - equipped appliances, the total volume of flue gas is 30 ft3 for each 1 ft3 of natural gas burned in the combustion ...

    Get Price
  • House Water Heater Vent Pipe Tips & How To Do It Right ...

    2008-3-19 · On top of natural draft gas water heater, in its center section, right above the water heater vent, you should have a draft hood installed. It sits on 3-4 short legs, sometimes secured to the water heater top plate with screws, or ( depending on design ) has its legs shaped like pins or hooks at the end, inserted into the holes in water heater ...

    Get Price
  • ProLine® XE SL Power Direct Vent 50-Gallon ... - Hot Water

    Product Description. The ProMax® SL Power Direct Vent gas water heater offers horizontal and vertical venting options and features a two-pipe venting system that draws clean air from outside the home, eliminating any worries about indoor ventilation. Featuring a 50-gallon (nominal) tank and a 60,000 BTU propane burner, the GPDX-50L (LP) Power ...

    Get Price
  • Water Heating System - Water Heater Malaysia

    2018-10-19 · Water Heater Malaysia. Water heating is a warmth exchange process that uses a vitality source to warm water over its underlying temperature. Run of the mill household employments of hot water incorporate cooking, cleaning, washing, and space heating. In industry, hot water and water warmed to steam have numerous employments.

    Get Price
  • Home

    FIMACO SDN BHD (110749-V) GST No: 001701969920 (A Member of Fiamma Holdings Berhad) 8-2, Wisma Fiamma, No. 20, Jalan 7A/62A, Bandar Manjalara, 52200 Kuala Lumpur, Malaysia.

    Get Price
  • Series MI Series MIHII - PB Heat: Peerless® Boilers

    2019-11-5 · The design of this boiler is certified for alcove installation with the following clearances: 1. 6″ (152 mm) between sides and combustible construction. 2. 24″ (610 mm) between top of jacket and combustible construction. 3. this boiler on non-combustible flooring or use a 6″ (152 mm) between draft hood and combustible construction.

    Get Price
  • DXL Series

    2021-9-2 · DXL Series. Dunkirk's DXL Series of gas-fired hot-water boilers have an advanced Fuel Smart Hydrostat Control and offers up to 83.5% AFUE. Energy saving features include the electronic ignition system and motorized vent damper to reduce your heating costs. Features a dependable cast iron heat exchanger with cast iron push nipple connections.

    Get Price
  • VENTING VENTING Gas AppliancesGas Appliances

    2013-6-18 · Draft-hood units require an additional 14 or 15 cu.ft. of dilution air for each 1 cu.ft. of fuel consumed, producing roughly 30 cu.ft. of relatively drier exhaust products for the flue to handle. (The ratios are slightly different for propane, but the principle is the same.) This difference between fan-assist and draft-hood performance has an ...

    Get Price
  • GOLD SERIES GAS BOILERS - Weil-McLain

    2020-5-20 · CGa boilers are C.S.A. design certified for installation on combustible flooring. DIMENSIONS STANDARD EQUIPMENT: Factory Tested Two-Piece Top Jacket Panel Insulated Extended S teel Jacket Cast Iron Sections with Built-in Air Separator Radiation Plates Vertical Draft Hood Automatic Vent Damper Combination Gas Valve

    Get Price
  • Caron Heating & Cooling, Inc., Boilers - Methuen, MA, Rheem

    If your home has hot water radiators in each room for heat, you have a boiler to heat the water. Like a furnace, the energy efficiency of a boiler is given as the Annual Fuel Utilization Efficiency (AFUE). Boilers manufactured since 1992 must have an AFUE of at least 80%. We offer a complete line of gas and oil boilers starting at 80% AFUE and up.

    Get Price
  • SHB02 -pg 30 -60b

    2021-7-14 · gas is exhausted for each 1 ft of natural gas consumed. Now consider the fact that for every 15 ft3 of flue gas going up the flue, an equal volume of dilution air is added at the draft hood. Therefore, for typical draft hood - equipped appliances, the total volume of flue gas is 30 ft3 for each 1 ft3 of natural gas burned in the combustion ...

    Get Price
  • House Water Heater Vent Pipe Tips & How To Do It Right ...

    2008-3-19 · On top of natural draft gas water heater, in its center section, right above the water heater vent, you should have a draft hood installed. It sits on 3-4 short legs, sometimes secured to the water heater top plate with screws, or ( depending on design ) has its legs shaped like pins or hooks at the end, inserted into the holes in water heater ...

    Get Price
  • ProLine® XE SL Power Direct Vent 50-Gallon ... - Hot Water

    Product Description. The ProMax® SL Power Direct Vent gas water heater offers horizontal and vertical venting options and features a two-pipe venting system that draws clean air from outside the home, eliminating any worries about indoor ventilation. Featuring a 50-gallon (nominal) tank and a 60,000 BTU propane burner, the GPDX-50L (LP) Power ...

    Get Price